Product grain: maple grain
Product specification: Infinite length/15 * 1.8 * 4.5
Product color: Maple wood
Product strap: Glass fiber mesh cloth stable strap
Bottom plate structure: Y-shaped anti movement pattern
Product application: basketball sports venues and sports venues for general basketball games
Product warranty: 8 years
Professionalism: The pattern is designed according to the texture of the wooden floor, giving it a sense of texture, and the venue presents a beautiful and beautiful appearance.
Skid resistance: Anti slip surface layer with moderate floor friction.
Sex: The pattern is relatively flat, reducing the abrasions caused by athletes falling to the ground during competition; And the wood grain design can effectively disperse the focus of stadium lighting, without causing trouble to the athlete's vision, allowing the athlete to focus their mind.
Wear resistance: Strengthen the wear-resistant structure to provide durable wear protection.
High protection: High density PVC foam layer with zero calcium powder added to ensure excellent impact absorption performance of the floor, effectively protecting the joints of athletes.
Comfortable foot feel: Made of high-quality materials and professional structural design, the floor ball has a high rebound rate, is elastic and resilient, and is comparable to the true touch of sports wood flooring.
Dimensional stability: The structure is reinforced with fiberglass mesh fabric, ensuring stable floor dimensions.
Environmental Protection and Health: Using high-quality PVC raw materials, environmentally friendly plasticizers, free from harmful substances such as formaldehyde and heavy metals, the flooring is environmentally friendly, ensuring a healthy sports environment.
Prevention of deviation: The Anglo anti-counterfeiting "Y" pattern backboard has good floor adhesion and can effectively prevent site deviation.
——Working conditions for laying PVC sports flooring——
1. The construction ground should be clean, flat, long-lasting dry, sturdy, and free from dust and dirt.
2. The flatness of the base layer should be within 2 meters of a straight edge, and the drop in rotation should be less than 3 millimeters. Otherwise, the ground treatment should be carried out in advance.
3. It is advisable to operate at an indoor temperature of 15 ℃.
4. The requirement for indoor air humidity should be between 20% -75%.
The detection and treatment of the ground base layer is directly related to the construction quality of self leveling, and the quality of self leveling is directly related to the effectiveness and service life of PVC floor laying.
PVC floor self-leveling cement layer
Step 1: Five requirements for grassroots testing and treatment: sturdy - the tensile strength is greater than 1.5Mpa; Cleaning - treat with a vacuum cleaner or saw dust; No grease - clean the grease area with low concentration alkaline solution; No gaps - after filling with foam adhesive, apply cement mortar evenly; Leveling - Use cement mortar to coat uneven areas evenly. The height difference within a range of two meters shall not exceed 3mm.
Step 2: Apply the interface agent. Purpose: To seal the base layer and prevent premature loss of moisture in self leveling mortar; Enhance the bonding strength between the ground base and the self leveling mortar layer; Prevent the generation of bubbles; Improve the flowability of self-leveling materials. The interface agent needs to be applied twice, with an interval of 2-3 hours between applications After the interface agent dries, proceed to the next step.
Self leveling interface agent diagram
Three steps: cement self leveling. Partition with Continuous pouring of a complete area at once; First, clean water should be used everywhere in the mixing bucket, and then cement should be added. Stir with an electric mixer until the consistency is uniform and there are no lumps in the liquid slurry. Pour the stirred flow self leveling material onto the base surface within the construction time, allowing it to flow flat like water. Wear nail shoes on uneven areas and scrape them flat with a scraper, and use a deflating roller to roll the poured self leveling ground to remove the air brought in during mixing and avoid bubbles.
——Construction and paving methods for sports flooring——
The floor is unfolded in advance and laid flat on the ground Above, and the on-site temperature should not be lower than 15 ℃. After the floor is restored, an additional 5cm should be left in both sections during cutting.
Method 1: Mobile pavement:
The floor and floor are bonded together using a dedicated single-sided connection tape provided by the manufacturer
The floor is not bonded to the ground for easy future movement
Method 2: Local fixed paving method:
Apply 10cm of adhesive to the inside of the floor based on the edge line of the floor
Alternatively, use a specialized double-sided connection tape provided by the manufacturer for bonding
Method 3: Full adhesive bonding and paving method:
The floor and ground are all glued together. The basketball court adopts full adhesive bonding, otherwise when the ball comes into contact with the ground, it will affect the rebound of the ball.
Method 4 Welding method:
Firstly, open the back of the sheet upwards, align the gaps, and directly perform slot welding;
(When double-sided welding is completed, weld two bumpers at 3cm on both ends of each plate, and then perform slot welding on the opposite side of the plate.)
——Cleaning and maintenance of sports flooring——
1、 PVC floor protection
1. Sand and stone protection: Place a sand and stone protective mat at the entrance of a room or hall using PVC flooring to prevent shoes from bringing sand and stone into the room and scratching the floor surface.
2. Item handling protection: When handling items, especially sharp metal objects at the bottom, do not drag them on the floor to prevent injury to the floor.
3. Smoke and fire protection: Do not place burning cigarette butts or high-temperature metal objects directly on the floor to prevent floor damage.
4. Chemical protection: Avoid a large amount of water staying on the floor surface for a long time. Soaking the floor with water for a long time may penetrate under the floor, causing the floor adhesive to dissolve and lose its adhesion, and also easily causing the floor to bulge and deform.
5. Sunshine protection: Avoid direct exposure to strong light. Long term exposure to ultraviolet radiation can cause discoloration and fading of the floor.
2、 PVC floor maintenance
1. Regular floor maintenance: PVC floors should be cleaned with neutral cleaning agents, and strong acid or alkali cleaning agents should not be used to clean the floor. Regular cleaning and maintenance work should be done well;
2. Daily maintenance: Use a vacuum cleaner for vacuum cleaning, or use a clean 90% dry mop to clean the ground, and locally clean severely polluted areas;
3. Monthly maintenance: Clean the ground and wax the partially damaged foundation.
4. Pollution treatment: The ink, food, oil, and other stains on the PVC floor should be wiped off, and then the traces should be wiped off with a diluted cleaning agent. The remaining black shoe offset can be wiped off with the Inlio black offset remover, and then washed with clean water.
5. Attention: Floor cleaning should not be done with cleaning balls or knives, and chemicals such as acetone, toluene, etc. should not be used indiscriminately. For dirt that cannot be cleaned using conventional methods, please consult professional after-sales personnel at Inlio.
top